Contact Dermatitis ; 88(5): 383-388, 2023 May.
Article En | MEDLINE | ID: mdl-36802059

BACKGROUND: Five workers from an industry manufacturing various articles from carbon fibre reinforced epoxy plastics were referred to our department because of suspected occupational allergic contact dermatitis (OACD). When patch tested, four of them had positive reactions to components of epoxy resin systems (ERSs) that could explain their current skin problems. All of them had been working at the same workstation at a specially designed pressing machine, with operations including manually mixing epoxy resin with hardener. Multiple cases of OACD in the plant prompted an investigation including all workers with possible risk exposures at the plant. OBJECTIVES: To investigate the prevalence of occupational dermatoses and contact allergies among the workers at the plant. MATERIALS AND METHODS: Totally 25 workers underwent investigation that included a brief consultation with a standardized anamnesis and clinical examination followed by patch testing. RESULTS: ERSs-related reactions were found in 7 of the 25 investigated workers. None of the seven had a history of previous exposure to ERSs and they are regarded as sensitized through work. CONCLUSIONS: Twenty-eight percent of investigated workers showed reactions to ERSs. Of these the majority would have been missed if supplementary testing would not have been added to testing with the Swedish base line series.


Dermatitis, Allergic Contact , Dermatitis, Occupational , Humans , Dermatitis, Allergic Contact/diagnosis , Dermatitis, Allergic Contact/epidemiology , Dermatitis, Allergic Contact/etiology , Epoxy Resins/adverse effects , Dermatitis, Occupational/diagnosis , Dermatitis, Occupational/epidemiology , Dermatitis, Occupational/etiology , Patch Tests/adverse effects , Industry
2.
Contact Dermatitis ; 83(4): 301-309, 2020 Oct.
Article En | MEDLINE | ID: mdl-32608015

BACKGROUND: Several cases of allergic contact dermatitis (ACD) to the glucose sensor FreeStyle Libre have been reported. Isobornyl acrylate (IBOA) and N,N-dimethylacrylamide (DMAA) are known culprit allergens. OBJECTIVES: To evaluate patients with suspected ACD to FreeStyle Libre in a standardized manner, present causative allergens, and assess patient-reported implications. METHODS: A total of 15 patients with suspected ACD to FreeStyle Libre were patch tested with the Swedish baseline series and a new medical device series. IBOA and DMAA were tested at 0.1% and 0.3% in petrolatum (pet.). Readings were performed on day (D) 3 and D7. Background data, details on skin reactions, and associated implications were assessed using a questionnaire. RESULTS: Thirteen patients were sensitized to IBOA and four to DMAA. Two positive reactions to IBOA and one to DMAA were seen only at 0.3% concentration on D7. Median duration of sensor use before dermatitis onset was 6 months. Half the number of the patients took precautions in everyday life due to sensor-related skin reactions. Six patients discontinued sensor usage. CONCLUSIONS: Patients with suspected ACD to glucose sensors should be evaluated with a relevant patch test series containing IBOA and DMAA. Adding the 0.3% pet. concentration is recommended. The reading on D7 is necessary.


Acrylamides/adverse effects , Acrylates/adverse effects , Allergens/adverse effects , Blood Glucose Self-Monitoring/adverse effects , Camphanes/adverse effects , Acrylamides/administration & dosage , Acrylates/administration & dosage , Administration, Cutaneous , Adult , Allergens/administration & dosage , Camphanes/administration & dosage , Diabetes Mellitus, Type 1/blood , Diabetes Mellitus, Type 2/blood , Female , Humans , Male , Patch Tests/methods
...